Unit 14: Workplace Safety and Health




               the feed-end of a cotton opener is in a room which is separated from the delivery-end by  Notes
               partition extending to the roof or to such height as the factory inspector may express in
               writing,  women and children  may be  employed in  that  part  of the  room where  the
               feed-end is kept.
          8.   Hoists and  Lifts (28):  In every factory hoists and  lifts shall  be of a good  mechanical
               construction, sound material and adequate strength and shall be properly protected by
               enclosures fitted with gates. Once in every six months, it shall be thoroughly examined by
               a competent person. The maximum safe working load shall be clearly indicated on every
               hoist or lift. A heavier load shall not be allowed to be carried on that hoist or lift.

          9.   Lifting Machines, Chains and Ropes (29): The lifting machines, tackles, chains and ropes
               used in every factory should be of good construction, sound material and strong enough
               to carry the necessary loads.
          10.  Revolving Machinery (30): In every room where grinding jobs are performed, a notice
               showing the maximum working speed of the machine shall be fixed near it. Safe working
               peripheral speed of every revolving vessel, pulley, basket, flywheel, disc has to be observed
               and steps should be taken to see that the safe working speed is not exceeded.

          11.  Pressure Plant (31): If in any factory operations are carried out at a pressure above the
               atmospheric pressure, proper measures shall be taken to see that the safe working pressure
               is not exceeded.
          12.  Floors, Stairs and Means of Access (32): All doors, steps, stairs, passages and gangways
               shall be of sound construction and maintained in a state of good repair; they shall be free
               from obstructions likely to cause persons to slip and hand rails shall be provided wherever
               required. As far as possible, safe means of access to the place of work shall be provided and
               maintained.
          13.  Pits, Sumps, openings in Floors (33): Every pit, tank, sump, fixed vessel, opening in the
               ground or in a floor which is a source of danger, shall be either properly covered or
               securely fenced.
          14.  Excessive Weights (34): No person shall be employed in any factory to lift, carry or move
               any load which is so heavy as to cause him a possible injury.
          15.  Protection of Eyes (35): Effective screens or suitable goggles be given to workers while
               scrutinising a manufacturing process involving risk of injury to eyes.
          16.  Dangerous Fumes and Gases (36): No person shall be allowed to enter any chamber, tank,
               vat, pit or other confined space in which any gas, fume, vapour or dust is likely to be
               present to a dangerous extent. A person can enter such a place only when it is provided
               with a manhole of adequate size or other effective means of egress. A person may be
               allowed to enter such a space only when suitable steps have been taken to remove dangerous
               fumes. In case of any emergency, suitable breathing apparatus, reviving apparatus, belts
               and ropes be kept ready. A sufficient number of persons in the factory shall be trained in
               the use of all such apparatus and in the method of restoring respiration.

          17.  Precautions with regard to Portable Electrical Light (36A): No portable electric light or
               any other electric appliance of voltage exceeding 25 volts shall be permitted for use inside
               any chamber, tank, vat, pit, flue or confined place. If any inflammable gas, fume or dust is
               likely to be present in such chamber, tank, vat, pipe flue or any other confined space, no
               lamp or light, other than the one which is flame-proof shall be permitted to be used inside
               the factory.